Discard in accordance with national or local regulations. Press and hold the Memory Button for at least 3 seconds to delete all the readings. After cleaning or disinfecting, wait at least 10 minutes prior to taking another measurement. Failure to understand and observe any warning statement in this manual could lead to patient illness, injury, or death. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. Warning: This product may contain a chemical known to the state of California to cause cancer, birth defects, or other reproductive harm. Warning and caution statements may appear on the thermometer, its packaging, shipping container, or in this instruction manual. It stays in our bathroom. 51 0 obj <> endobj $15.99 ADC Acrylic Wall Cradle for Adtemp 429 Thermometer. AdTemp 429 Infrared Thermometer – Non-Contact Dr’s Toy Store is now offering the AdTemp 429 Infrared Thermometer – Non-Contact which features an infrared sensor that reads temperature from the middle of the forehead. Caution: To avoid accuracy concerns, make sure that the thermometer’s lens is clean and intact prior to use and after measurement is complete. $5.49 Regular Price $5.49. Rectal thermometers are considered the most accurate while forehead thermometers come in second. Required fields are marked *. ADC Thermometer. Use this thermometer on a clean dry forehead. Non-Contact Thermometer. Measurement is read in just 1 second with an audible beep sounding when this is complete. Description: Adtemp Temple Touch 427 Ultra-fast response and cost effective design makes the Adtemp 427 ideal for pediatric and institutional use.Adtemp Temple Touch 427 Ultra-fast response and cost effective design makes the Adtemp 427 ideal for pediatric and institutional use. ADC 429 ADTemp non-contact thermometer. It’s a safe and comfortable experience that minimizes the risk of cross-contamination. Specific warnings and cautions are also found throughout this manual. Caution: Contact ADC or your local ADC representative for any assistance with this device. You’ll quickly appreciate the results, for you now own one of the finest Non-Contact thermometers that money can buy. Questions about your Manual ? Warning: Dispose of this thermometer and its batteries in accordance with local or national regulations for electronic waste. Shipping, Storing, and Environment Symbols. Pressing these buttons again will change the scale back to Fahrenheit. Use a Phillips head screwdriver to loosen battery cover screw. The AdtempTM 429 Infrared Thermometer features: Infrared sensor simplifies temperature measurement-ideal for screening Measures in about 1 second without patient contact eliminating the concern of cross contamination or costly probe covers Measurement feedback system signals proper operating distance for accuracy Measures at a distance of 4-6cm (1.5″-2.5″) from patient’s forehead … b. Description Adtemp 429 Non-Contact Thermometer The Adtemp 429 Non-Contact Thermometer features an infrared sensor that reads the temperature from the middle of the forehead with no skin contact required for a safe and comfortable experience that minimizes the risk of cross-contamination. This thermometer is calibrated at the time of manufacture. The ADTEMP 429 Non-Contact Thermometer features an infrared sensor that reads temperature from the middle of the forehead with no skin contact required in 1 second for a safe and comfortable experience that minimizes the risk of cross-contamination … Caution: Observe proper measurement distance, starting between 4 and 6 cm from the patient’s forehead. 7. Database contains 1 ADC Adtemp 429 Manuals (available for free online viewing or downloading in PDF): Operation & user’s manual . The Adtemp 429 Non-Contact Thermometer features an infrared sensor that reads temperature from the middle of the forehead with no skin contact required for a safe and comfortable experience that minimizes the risk of cross-contamination. Your email address will not be published. Observe correct polarity when inserting new batteries. 3. The unit will emit a short beep (except in night mode), and the backlit display will illuminate when the measurement is complete. A night mode silences this beep. Type Non-Contact infrared thermometer Model no. move the thermometer toward the patient UNTIL you have reached the correct distance - between 1.5 - 2.5 inches (4 - 6cm) from the center of the forehead. FC-IR101 Non-Contact Thermometer Instruction Manual, MedicSpa Non-Contact Forehead Thermometer Instruction Manual, VeraTemp V32035 Non-Contact Thermometer Instruction Manual, Non-Contact Digital Thermometer KI-8271 Instruction Manual, Beurer FT 90 Thermometer Instruction Manual, Beurer FHT 6 / FT 45 Thermometer Instruction Manual, Adorne Collection Switches/Dimmers/Outlets User Manual, SmartCode Lever Installation & Programming Manual, TWS True Wireless Stereo Earphones User Manual [AirPod Look-a-Likes], Anker Zolo Liberty Bluetooth Headphones User Manual. Post in the comments! Convenient, non-contact measurement makes the Adtemp™ 429 the ideal instrument for use on all patients; ADTEMP™ 429 IR thermometer features: Reads in 1 second; Large 6mm illuminated display; Measuring range (Human) 50.0°F - 122.0°F +/- .5°F (10°C - 50°C +/- .3°C) Accept Cookies. Note: Ensure that the thermometer is held firmly during measurement and that the patient does not move until the measurement is complete. Please consult applicable local or national laws in the place of use to ensure that the requirements for the control of the measurement, functionality, and accuracy of the device are maintained for your specific uses. 131 0 obj <>stream Caution: Stop using this device if it operates erratically or if the display malfunctions. Find helpful customer reviews and review ratings for ADC Non Contact Infrared Thermometer, Adtemp 429,White at Amazon.com. The default temperature scale is Fahrenheit. The cover is easy and clear view too. Select the desired mode by pressing and releasing the Human/Object button. %PDF-1.4 %���� Please include your name and address, phone no., proof of purchase, and a brief note explaining the problem, your return address and $2.00 to cover shipping and handling. Do not allow children to take their temperature with this thermometer unattended. ADC's Adtemp 429 Non-Contact Thermometer features an infrared sensor that reads temperature from the middle of the forehead with no skin contact required. To recall previous readings: Note: The Human or Object symbols will be displayed to indicate the measurement mode that was in use for the displayed reading in memory. The LCD displays “–” and the device beeps to confirm all the memories are cleared. (excluding Night modes). ADTEMP 429 Thermometer and other Thermometers at PCRichard.com ADC 427 Digital Temple Touch Thermometer; readings in six seconds; fast, accurate readings of core body temperature; non-invasive touch to the temple; large, digital display in Fahrenheit or Celsius; temperature range 95 - 107.6 F (35 - 42 C) It can also be used to measure the temperature of objects. Recommendations for calibration do not supersede any legal obligations that you may have in relation to this equipment. Note: When taking a patient’s temperature, ensure that the thermometer is in Human mode; the Human symbol will appear on the display. This is essential to the accuracy of the measurement. If you have an electronic thermometer or frontal thermometer with more functions, you will usually have a “MODE” key or “℃/℉” key above the thermometer. !�!���J�9B��Mtk�������t���I/^o���宿����S�ä�1�:�q�n���S�4���QY2.�>ֶj��>Y�X��xof��E�:�p��"D�$�W�{�-4n� ��6>�N�~q�_(�L�%C�ȡ���E��7�/1�P���\�W�g������D��e��e��s�VT���]����m��d/W�"%{�0�5�[��$�KQ"~��-�1�3x����1�H��nƛ�� U��g������Ʒ�oT���Y"d�n. 6. Slowly move the device towards the patient’s forehead. Thank you for choosing an ADC® AdtempTM Non-Contact thermometer. The Adtemp 429 Non-Contact Thermometer features an infrared sensor that reads temperature from the middle of the forehead with no skin contact required for a safe and comfortable experience that minimizes the risk of … Press and release the Multi-Function button, all segments will be displayed along with a single audible beep (Figure 1). Once the correct distance is reached (about 1 inch or 3 cm), an amber light will flash just below the Mode and Memory buttons. Before using the thermometer, users must familiarize themselves with the general safety information included below. ADC Adtemp Temple Touch Thermometer Standard ADC427Q . Thermometer Sale with FREE shipping. Forehead thermometers measurements fall within 0.4 degrees. If the thermometer is operated in accordance with these instructions, periodic readjustment is not required. Each press of the Memory button will display a previous measurement (up to 30). h�bbd```b``v��`�3��Dj��Z�@��y)�D�����$��������\�@$�)�c"�@$G$��"9!l^�8{'��: vH��#���.a`%I&�30�0 $ Note: If the distance of the thermometer is too far from or too close to the patient’s forehead, the dash icons will continue to rotate and the unit will beep (except in night mode) UNTIL the correct distance is obtained. Briefly press and release the Memory button then press again to display the last measurement accompanied by the. You should determine the requirements for personnel, equipment, and materials necessary to achieve your desired disinfection levels and may need to employ routine monitoring of your disinfection protocols within your facility. Caution: Avoid pointing the infrared sensor at any heat source other than a patient. 1. High, prolonged fever requires immediate medical attention, especially for young children. Press the Measure button to power the unit on. 4. %%EOF NOTE: At 80 MHz and 800 MHz, the higher frequency range applies.NOTE: These guidelines may not apply in all situations. Caution: If battery leakage occurs, fully clean the battery compartment using personal protective equipment prior to re-use. 77 0 obj <>/Filter/FlateDecode/ID[<77FA7A0F356B77459C8F4DC4D05A2215>]/Index[51 81]/Info 50 0 R/Length 126/Prev 773393/Root 52 0 R/Size 132/Type/XRef/W[1 3 1]>>stream Press the Measure button to power on the thermometer. Press and release the Measure button making sure not to obstruct your view of the LED display or the buttons area. If the batteries are completely depleted, “Lo” will be displayed along with the low battery symbol. We’re proud of the care and quality that goes into the manufacture of each and every item that bears our name. $149.99 FLIR Extech Non-Contact Forehead IR Thermometer.